Vers CM (Connection Module): 5-in-1 multi-function device for connecting wired probe and tool setter to controller:
1. Multiplexer - combining the signals of two sensors into one common output.
2. Converter - any type of sensors at the input and any type of output (PNP-NPN-NC-NO).
3. Anti-bounce - 0, 5, 25, 100 ms.
4. Anti-vibration - ignores triggers from shock and vibration.
5. Protection - against short circuit, polarity reversal, overload, overvoltage.
This device is designed for easy connection to the controller of any wired sensors, including third-party sensors.
Connection example
We recommend connecting cable shields to the SHIELD pins on both the input and output. By default, the CM has a SHILD-GND jumper installed. If your controller already has a SHILD-GND connection installed, then the jumper in the CM can be removed.
Purpose of DIP-8 Switch
NO - normally open connection
NC - normally closed connection
Anti-bounce OFF (input - yellow graph, output - green)
Anti-bounce ON
Anti-vibrationOFF
Anti-vibration ON (a fixed 5ms delay is added, which should be taken into account when measuring)
Connection Vers CM + Vers PR + Vers TSm: