► Сompare Vers WLR v9 and v7.5
Vers WLR v9 features
1. Unidirectional repeatability 0.001 mm.
2. Tungsten carbide pin-ball contacts.
3. Over travel limit (X,Y) ±10mm, (Z) -7mm
4. Li-ion rechargeable battery LIR2477 3.6v is used, at the same time, the voltage on the contact group is dynamically increased to 16 V for reliable contact closure.
5. Ultra-low probe current consumption:
- 0.4 ma when work, continuous radio communication implemented,
- 0.02 ma in sleep mode,
- 0 ma when the power button is off.
The frequency of recharging with daily use is on average 1-2 times a month, the charging time is 1 hour. You can continue to use the sensor when charging from the receiver. Charging is also possible from any 5 volt chargers. Probe trigger signal will be transmitted through type-c cable when probe is connected to receiver with cable. This can be useful in some cases, such as when there is strong radio interference.
6. A vibration sensor allows to wake up from sleep by shaking or rotating in the spindle from 200 rpm.
7. Splash and dust protection.
8. Receiver features:
- Provides normally closed communication with the probe, or in other words, continuous radio communication by receiving short signal packets from the probe with a frequency of 2 to 5 times per second (user-defined or can be disabled). The reliability of a normally closed circuit over a radio channel is ensured by a protocol with confirmation of reception and duplication of unconfirmed data.
- Radio delay is 0.75 milliseconds, delay in the entire chain from the ball contacts of the probe to OUT pin of the receiver is 1.5 milliseconds.
- Radio signal level indication every time you press the stylus.
- Battery level indication.
- Automatic search for the best of 16 2.4 GHz sub-bands when the probe is turned on or awakened.
- Power sources in a wide range of +5V ... +24V at the input and at the output.
- Available NPN-PNP, NC-NO schemes of connection to the CNC controller.
- Input pin for NPN-NC or NC toolsetter.
- The ability to set sleep modes with dip switch.
- Detector of delays over 1.7 ms and output a warning to the ERR output pin.
- LED and buzzer indication of probe triggering, LED indication of error signal.
- Protection against short circuits of the outputs to power or ground, from power reversal.